Ethernet and Gun Mover Configuration
4-26
Part 1056418-07
E
2019 Nordson Corporation
Variable Mode: Overtravel Settings Negative, Restricted Pattern
Top Turn-Around
Bottom Turn-Around
Top Overtravel
Bottom Overtravel
Reciprocator Home (0)
Top Soft Limit
Bottom Soft Limit
Figure 4-21 Variable Mode: Overtravel Settings Negative, Restricted Pattern
Air Flow Percent Adjust Control
This function allows you to control powder pump flow-rate and atomizing air
flow based on stroke length. It can only be used with the two variable
stroke modes.
This button becomes active when a variable mode is selected;
otherwise it is grayed out. Touch it to open the Air Flow Percent Adjust
Control screen shown in Figure 4-22. When the percent adjust function is
enabled the button is green.
This function changes flow-rate and atomizing air by percentages as the
stroke length increases or decreases. As the reciprocator is commanded to
a given stroke length the change is sent to the gun control cards associated
with the reciprocator.
NOTE:
This function only supports a single row of guns on a reciprocator.
If the reciprocator has multiple rows of guns, only the configured guns on
the reciprocator are sent the percent changes. Refer to Guns on
Reciprocator in the Standard Reciprocator Configuration Settings table on
NOTE:
Percent Adjust is an additive variable. These Percent-Adjust
settings are added or subtracted from Reciprocator Preset Percent Adjust
settings, Global Percent-Adjust settings, and Conveyor Speed
Percent-Adjust settings.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...