Ethernet and Gun Mover Configuration
4-21
Part 1056418-07
E
2019 Nordson Corporation
Standard Reciprocator Configuration Settings
Standard Reciprocator Configuration Settings
Side of Booth
(5)
If in/out positioners have been configured first as recommended
then this setting will be grayed out it is always assumed that
reciprocator 1 is mounted on positioner 1.
If your system has reciprocators only, then select the side of the
booth the reciprocator is physically located on (right or left).
NOTE:
The reciprocator numbers on the Main screen change to
match this setting. The Reciprocator 1 control screen controls
physical reciprocator 1 if the node configuration was done in the
correct order. Refer to
Node Configuration
Soft Limits
(8, 9)
The soft limit positions are measured from the zero (0) position. Set
the soft limits so the reciprocator never contacts the top and bottom
limit switches during normal operation.
Tripping the limit switches during any movement other than a Home
will cause a fault and require a reset from the alarm screen.
Hysteresis
(23)
Slop compensation. This setting prevents the reciprocator from
hunting when sent to the Park position. If the reciprocator stops
within this distance from Park it will not move again in an attempt to
stop exactly on the Park position. Set this value to a 0.5 or less and
adjust as necessary.
Park/Clean
Position
(21)
This is the position that you want the reciprocator to move to:
S
when the Park button is touched.
S
when a color change sequence is started (application specific,
consult with your Nordson controls engineer).
Spray Pattern
Width
(26)
Width, in inches or millimeters, of one spray gun fan pattern. If your
spray gun fan patterns overlap, then enter the average fan pattern
width (total fan width of all guns / number of guns).
Number of Laps
(25)
Number of times the effective fan width passes over a certain point.
Typically, the more laps the better the powder coverage will be:
2 = normal
4 = fine
6 = extra fine
For any given conveyor speed, the greater the number of laps, the
faster the reciprocator speed required. Make sure that the
reciprocator speed does not cause the fan pattern to collapse. If
the fan pattern collapses or the maximum speed is exceeded then
select a lower number of laps.
Use the lap calculator on the Reciprocator Control screens to see
the effect of each selection.
Guns on
Reciprocator
(24)
Starting and ending number of the guns on the reciprocator. For
example, 1 and 4 means that guns 1, 2, 3, and 4 are on the
reciprocator. The gun numbers must be unique; you cannot have
gun number 3 on both reciprocator 1 and 2.
NOTE:
The iControl system supports only one horizontal array of
guns. It does not support multiple stacks of horizontal guns.
Master/Slave
Select
(18)
Allows you to slave reciprocators to the current reciprocator. The
settings for the master are then used for the slaves. In Figure 4-13,
reciprocator RC2 is slaved to reciprocator RC1.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...