Ethernet and Gun Mover Configuration
4-5
Part 1056418-07
E
2019 Nordson Corporation
Node Configuration
Refer to Table 4-1 and Figure 4-4. The nodes are devices on the Ethernet
network such as the positioner, reciprocator, or analog scanner controllers.
Touch the
Node Configuration
button on the Network Status screen to
open the Node Configuration screen.
Security Login:
This button opens the Login screen so Nordson CSRs can
log in and change settings.
1. Enter the
MAC Address
,
TCP/IP Address
, and
Machine Type
for each
node on the network, as described in Table 4-1. If you make an invalid
entry the field will turn yellow.
When entering the machine type, select the field, then use the rotary dial
to toggle through the possible selections:
Heading
GP1 through GP4 (positioners 1 through 4)
GP1_RC1 (positioner 1 and reciprocator 1)
RC1 through RC4(reciprocators 1 through 4)
GP2_RC2 (positioner 2 and reciprocator 2)
GP1_GP2 (positioners 1 and 2)
GP3_RC3 (positioner 3 and reciprocator 3)
GP3_GP4 (positioners 3 and 4)
GP4_RC4 (positioner 4 and reciprocator 4)
RC1_RC2 (reciprocators 1 and 2)
PE (scanners)
RC3_RC4 (reciprocators 3 and 4)
Configure the positioners first, always entering them in numerical order. If
the system has reciprocators but no positioners, then configure the
reciprocators first, always entering them in numerical order.
If two positioners or reciprocators use the same controller, select a
combination such as GP1_GP2 or RC1_RC2. If one controller controls a
positioner and reciprocator, the system always assumes that reciprocator 1
is mounted on positioner 1 (GP1_RC1).
2. Touch the
Send IP Address
button or the
Save
button.
S
The
Send IP Address
button sends the IP addresses to the
controllers.
S
The
Save
button saves the data entries and sends the IP addresses
to the controllers if not done already.
iControl Versions Below 3.0
When you touch the
IP Send
or
Save
button, you are prompted to cycle
power on the node controllers by three messages. If you do not cycle
power correctly, the system will not be able to communicate with the nodes
on the network.
iControl Version 3 and Above Procedure
When you touch the
IP Send
or
Save
button, the following dialog box opens
and stay open until it is closed. You
must
now cycle power on the
controllers.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...