Spray Gun Preset Settings
5-14
Part 1056418-07
E
2019 Nordson Corporation
Select Charge Mode
(contd)
Select Charge Modes
Mode 0 (Off):
Turn Select Charge off to set kV or AFC.
Mode 1 (Recoat):
Use this mode for recoating parts that have already been coated and
cured. Gun current is aggressively reduced to eliminate back ionization.
Mode 2 (Special):
Use this mode for coating with special powders (dry blend metallics or
micas).
Mode 3 (Deep Cavity):
Use this mode for coating inside boxes or other deep cavities. Low
kV and current coats the front edges of the cavity and high kV and current coats the back of
the cavity.
Mode 4 (User Programmable):
This mode allows you to set both kV and
μ
A for a particular
part or powder and store the setting. The settings are loaded each time Mode 4 is selected.
Table 5-6 Select Charge Mode Values
Select
Charge
Mode
Application
kV/AFC
Setting
Initial kV Value
Max. Current
Prodigy/Encore
HD, Encore,
Sure Coat
Versa-Spray
All Guns
1
Recoat
not adjustable
95 kV
100 kV
15
μ
A
2
Special
not adjustable
60 kV
60 kV
30
μ
A
3
Deep Cavity, gun
inside
not adjustable
95 kV
100 kV
70
μ
A
4
User Programmable
adjustable
60 kV
60 kV
30
μ
A
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...