![background image](http://html.mh-extra.com/html/nec/express5800-140he/express5800-140he_user-manual_251170183.webp)
6-7
NOTES:
The maintenance partition, once created, will not be recreated again.
When the maintenance partition does not exist, some menu items do not appear.
–
Create Maintenance Partition
EXPRESSBUILDER creates about 55 MB of the maintenance partition on the system disk (or disk array
system) as work area. The various utilities are installed when the maintenance partition is created
successfully or when the maintenance partition is already created.
–
Install Maintenance Partition Utilities
Various utilities are installed in the maintenance partition from the CD-ROM.
–
Maintenance Partition Update
Various utilities are copied in the Maintenance Partition from the update disk. This menu is only used
when the update disk is supplied from your service representative or attached with your system.
–
FDISK
Execute FDISK command of ROM-DOS system. You can create/delete partitions, etc.
BIOS/FW/etc. Update
This menu allows you to update software modules such as BIOS and firmware of the server by using the
update disk (3.5-inch floppy disk) that is distributed from our customer service representative.
After rebooting the system, an update program is started automatically from the floppy disk, and the various
BIOS and firmware programs are updated.
IMPORTANT:
Do not turn off the server while the update program is running. If the
update processing is discontinued, the system becomes unable to start.
System Management
The parameters of BMC (Baseboard Management Controller) are set for remote control and alert.
Help
Displays explanations about various functions of EXPRESSBUILDER.
Return to the Top Menu
Choosing this menu returns to the Top Menu.
Содержание Express5800 140He
Страница 1: ... User s Guide Express5800 140He ...
Страница 2: ......
Страница 4: ...This page is intentionally left blank ...
Страница 18: ...x This page is intentionally left blank ...
Страница 38: ...2 8 Internal View 1 2 4 3 1 Power supply cage 2 Non hot plug PCI slot 3 Hot plug PCI slot 4 Fan bay ...
Страница 62: ...2 32 This page is intentionally left blank ...
Страница 199: ...6 23 Linux Enter the following command to start the program cd usr BmcOnlineUpdate BmcOnlineUpdate ...
Страница 201: ...6 25 Windows 2000 1 Select Setting Control Panel Add or Remove Programs 2 Click BmcOnlineUpdate ...
Страница 266: ...8 56 This page is intentionally left blank ...
Страница 336: ...B 6 This page is intentionally left blank ...
Страница 362: ...E 12 This page is left intentionally blank ...
Страница 378: ...G 12 ...
Страница 397: ......
Страница 398: ... ...