5-22
Exceptional Setup
This section explains how to setup by the exceptional way. You usually do not have to do as follows. The detailed
information is provided by the manual of the Mass Storage Device.
Installation of Mass Storage Device not Supported by ExpressSetup
If you would like to install or re-install the operating system when the system has new mass storage device not
supported by EXPRESSBUILDER, you have to set as follows.
1.
Read the manual supplied with the mass storage device before setting the server.
2.
If the mass storage device is a disk array controller, configure the RAID system before running
EXPRESSBUILDER.
3.
Boot the system from EXPRESSBUILDER CD-ROM.
4.
(a) When the Disk Array Configuration dialog box appears, check "Use Existing Array".
(b) Check "Apply OEM-FD for Mass storage device".
5.
Copy the driver for the mass storage device in the ExpressSetup.
Insert the floppy disk attached the mass storage device into the floppy disk drive.
Continue the ExpressSetup, referring to the on-screen messages.
Содержание Express5800 140He
Страница 1: ... User s Guide Express5800 140He ...
Страница 2: ......
Страница 4: ...This page is intentionally left blank ...
Страница 18: ...x This page is intentionally left blank ...
Страница 38: ...2 8 Internal View 1 2 4 3 1 Power supply cage 2 Non hot plug PCI slot 3 Hot plug PCI slot 4 Fan bay ...
Страница 62: ...2 32 This page is intentionally left blank ...
Страница 199: ...6 23 Linux Enter the following command to start the program cd usr BmcOnlineUpdate BmcOnlineUpdate ...
Страница 201: ...6 25 Windows 2000 1 Select Setting Control Panel Add or Remove Programs 2 Click BmcOnlineUpdate ...
Страница 266: ...8 56 This page is intentionally left blank ...
Страница 336: ...B 6 This page is intentionally left blank ...
Страница 362: ...E 12 This page is left intentionally blank ...
Страница 378: ...G 12 ...
Страница 397: ......
Страница 398: ... ...