4-22
Option Parameter
Description
Your
Setting
Boot
Monitoring
Policy
[Retry 3 Times]
Retry Service Boot
Always Retest
Appears when the boot monitoring feature is enabled. This
item indicates the processing at the occurrence of timeout
during boot monitoring.
If [Retry 3 times] is selected, the system is reset after the
occurrence of timeout and operating system boot is retried up
to three times. The failure in the third boot causes the boot to
be tried from the service partition.
If [Retry Service Boot] is selected, the system is reset after
the occurrence of timeout and operating system boot is
retried up to three times. Then the boot is tried from the
service partition for three times.
If [Always Reset] is selected, the system is reset after the
occurrence of timeout and operating system boot is retried
repeatedly.
Thermal
Sensor
Disabled
[Enabled]
Indicates whether the temperature sensor monitoring function
is enabled or disabled.
BMC IRQ
Disabled
[IRQ 11]
Indicates the IRQ of the BMC interrupt.
Post Error
Pause
Disabled
[Enabled]
Indicates whether POST is aborted once at the end of POST
if an error occurs during the execution of POST.
AC-LINK Stay
Off
[Last State]
Power On
Indicates the AC-LINK function. Shows the state of the power
of the server.
Power ON
Delay Time
[0] - 255
Sets the power on delay time when "Power On" or "Last
State" is specified for AC LINK.
FRU LED
Feature
Disabled
[Enabled]
Select "Enabled" to turn on the error lamp to identify the
location if the system detects a failure.
Clear FRU
LED
[No]
Yes
Select "Yes" to turn off the FRU LED. When the faulty
component is replaced, turn off the FRU LED.
Platform
Event
Filtering
Disabled
[Enabled]
Enables or disables the Platform Event Filtering feature of the
baseboard management controller (BMC).
[ ]: Factory-set
The table below shows the operation when the AC power to the server is turn off once and then on again, depending on
the setting of "AC-LINK."
Setting of AC-LINK
System status before AC power off
Stay Off
Last State
Power On
Operating Off
On
On
Aborting (DC power being off also)
Off
Off
On
Forced shutdown
Off
Off
On
* Press the power switch continuously at least four seconds. This forcibly turns off the power.
IMPORTANT:
Set this item to "Power on" in order to link the AC power source supplied
from UPS when the server is connected to UPS.
Содержание Express5800 140He
Страница 1: ... User s Guide Express5800 140He ...
Страница 2: ......
Страница 4: ...This page is intentionally left blank ...
Страница 18: ...x This page is intentionally left blank ...
Страница 38: ...2 8 Internal View 1 2 4 3 1 Power supply cage 2 Non hot plug PCI slot 3 Hot plug PCI slot 4 Fan bay ...
Страница 62: ...2 32 This page is intentionally left blank ...
Страница 199: ...6 23 Linux Enter the following command to start the program cd usr BmcOnlineUpdate BmcOnlineUpdate ...
Страница 201: ...6 25 Windows 2000 1 Select Setting Control Panel Add or Remove Programs 2 Click BmcOnlineUpdate ...
Страница 266: ...8 56 This page is intentionally left blank ...
Страница 336: ...B 6 This page is intentionally left blank ...
Страница 362: ...E 12 This page is left intentionally blank ...
Страница 378: ...G 12 ...
Страница 397: ......
Страница 398: ... ...