4-47
Others
1.
Select Adapter.
This menu item appears only if more than one MegaRAID host adapter is installed in the computer. Each
configuration is executed in increments of controller. Number of adapter is defined by PCI slot location.
2.
Clear Configuration.
Clears configuration information.
Select "Configure"
→
"Clear Configuration" from the TOP menu.
All configuration information on the disk array controller and hard disks is cleared when this function is
executed.
Configuration information on all channels of the disk array controller is also cleared with this function.
NOTES:
When configuration information on the disk array controller and the hard disk do not
match (excluding at replacement of faulty disk array controller), configuration cannot
be performed by selecting the configuration information on the disk array controller. In
this case, perform "Clear Configuration" to create configuration again.
MegaRAID Configuration Utility cannot delete each logical drive. Use Power Console
Plus.
3.
Make Online.
Puts a hard disk in the FAIL status online.
Select "Objects"
→
"Physical Drive"
→
(select hard disk)
→
"Make Online" from the TOP menu.
4.
Battery
–
Indicate battery information
Select "Objects"
→
"Adapter"
→
"Battery Information" from the top menu.
PRESENT
Backup Module
ABSENT
PRESENT
Battery Pack
ABSENT
GOOD
Temperature
HIGH
GOOD
Voltage
LOW
COMPLETED
Fast Charging
IN_PROGRESS
No of Cycle
***
–
Clear battery charge counter
Select "Objects"
→
"Adapter"
→
"Reset Battery Charge Counter" from the top menu. Popup message
appears. Select "Yes" and press
Enter
.
NOTES:
Clear Battery Charge Counter when you exchange the battery.
The battery backup module must be replaced every two years or 500 times of charge
and discharge.
Содержание Express5800 140He
Страница 1: ... User s Guide Express5800 140He ...
Страница 2: ......
Страница 4: ...This page is intentionally left blank ...
Страница 18: ...x This page is intentionally left blank ...
Страница 38: ...2 8 Internal View 1 2 4 3 1 Power supply cage 2 Non hot plug PCI slot 3 Hot plug PCI slot 4 Fan bay ...
Страница 62: ...2 32 This page is intentionally left blank ...
Страница 199: ...6 23 Linux Enter the following command to start the program cd usr BmcOnlineUpdate BmcOnlineUpdate ...
Страница 201: ...6 25 Windows 2000 1 Select Setting Control Panel Add or Remove Programs 2 Click BmcOnlineUpdate ...
Страница 266: ...8 56 This page is intentionally left blank ...
Страница 336: ...B 6 This page is intentionally left blank ...
Страница 362: ...E 12 This page is left intentionally blank ...
Страница 378: ...G 12 ...
Страница 397: ......
Страница 398: ... ...