4-9
Processor Settings
Selecting "Processor Settings" on the Main menu shows the following submenu.
See the table below for the items.
Option Parameter
Description
Your
Setting
Processor Retest
[No]
Yes
Clears the error information on the processor.
Processor Speed
Setting
–
Indicates the frequency of the processor.
Processor 1-4
CPUID
–
A numeral indicates the ID of processor. "Disabled"
indicates that the processor is defected by BMC.
"Not Installed" indicates that the processor is not
installed.
(Display only)
Processor 1-4
L2 Cache Size
–
Indicates the L2 cache of processor.
Processor 1-4
L3 Cache Size
–
Indicates the L3 cache size if the processor has L3
cache memory.
Hyper-Threading
Technology
Disabled
[Enabled]
Setting this item to "Enabled" allows the
hyper-threading technology to be used in the ACPI
mode. From operating system that supports
Hyper-Threading Technology feature, the specified
number of processors is twice as many as the actual
number of the installed processors.
With Windows 2000 Server / Advanced Server, the
operation of hyper-threading technology is not
guaranteed
Execute Disable
Bit
[Disabled]
Enabled
Disables or enables the Execute Disable Bit feature of
the processor.
Intel(R)
Virtualization
Technology
[Disabled]
Enabled
This menu appears only when the processor supports Intel
®
Virtualization
Technology.
Specify whether the Intel
®
Virtualization Technology is enabled or disabled.
If the parameter is changed, the DC power of the system must be turned off.
Select [Exit]
→
[Exit Saving Changes] and restart the system. Then, turn off
the DC power on POST screen.
Echo TPR
[Enabled]
Disabled
Specify whether Echo TPR is enabled or disabled.
This menu appears only on servers with Dual-Core Intel
®
Xeon
™
Processors.
[ ]: Factory-set
Содержание Express5800 140He
Страница 1: ... User s Guide Express5800 140He ...
Страница 2: ......
Страница 4: ...This page is intentionally left blank ...
Страница 18: ...x This page is intentionally left blank ...
Страница 38: ...2 8 Internal View 1 2 4 3 1 Power supply cage 2 Non hot plug PCI slot 3 Hot plug PCI slot 4 Fan bay ...
Страница 62: ...2 32 This page is intentionally left blank ...
Страница 199: ...6 23 Linux Enter the following command to start the program cd usr BmcOnlineUpdate BmcOnlineUpdate ...
Страница 201: ...6 25 Windows 2000 1 Select Setting Control Panel Add or Remove Programs 2 Click BmcOnlineUpdate ...
Страница 266: ...8 56 This page is intentionally left blank ...
Страница 336: ...B 6 This page is intentionally left blank ...
Страница 362: ...E 12 This page is left intentionally blank ...
Страница 378: ...G 12 ...
Страница 397: ......
Страница 398: ... ...