4-35
4.
When SCAN DEVICE is started (scanning information is displayed at the bottom of the screen) and ends, the
"New Configuration - ARRAY SELECTION MENU" screen appears.
5.
Move the cursor onto the hard disk to be packed by using cursor key and then press
Space
to select the hard
disk. (The display for the selected hard disk changes from READY to ONLIN and Axx-xx blinks.)
IMPORTANT:
The channel number displayed on MegaRAID Configuration Utility is
different form hardware channel number printed on the controller board.
Channel number printed on the board
CH0
CH1
Channel number displayed on MCU Channel-1 Channel-2
6.
When the hard disk is selected, press
Enter
to fix the selection (blinking stops.)