© MOOG 2010
This document is subject to MOOG INTELLECTUAL AND PROPRIETARY INFORMATION LEGEND . The details are on page II.
33
MRJ04410
LED’s (LIGHT EMITTING DIODEs)
The Led’s are used to indicate the status of various functions as follows:
Start
Lights when the cycle Start signal is received.
Die Gap
Lights when the Die Gap signal is received and “DIE GAP” on the LCD is lit
Continuous
Lit when the “Continuous Extrusion” machine type is selected
Accumulator*
Lit when “Accumulator” machine type is selected
Divergent
Lit when “Divergent” die gap tooling is selected
Convergent*
Lit when “Convergent” die gap tooling is selected
End of Filling
Lights at the end of the accumulator filling stroke
Point Out
Lights when each Marker point is reached
End of Extrusion*
Lights at the end of the accumulator extrusion stroke (Cushion)
*LED is lit in “
Figure 1-33
”
FUNCTION SWITCHES
Used to select the Functions F1 through F5 shown on the LCD display. These functions are:
F1 Profile*
Controls the parison wall profile and other related functions
F2 Marker
Set the program point markers. And set the slope for goes to Die gap and start potion.
And also Internal clock time setting.
F3 File
Controls the container wall thickness storage functions
F4 Monitor
Enables the I/O functions and indicates current value of servovalve input current and
die gap position
F5 Data
Displays the profile point and related function data
F1+SET
SET UP Mode – Provides die gap tooling and other machine related set up functions
F2+SET
Signal assign to Monitor Analog output
F3+SET
Delete and Backup/Restore the storage data. (Backup/Restore for data in SD card)
F4+SET
Machine setting setup
F5+SET
Communication parameter setting RS422 and Ethernet. And Internal clock time setting