DigiPackⅡ Manual, Installation and
Maintenance
1-1. Change from J141-214
The basic specification of DigiPack
Ⅱ
(J141-214A) is equivalent to conventional
J141-214.
Refer to the following table for a changed part.
Modify Items
J141-214
J141-214A
Comment
1 Timer Backup
Button cell.
Retention time is
about five years and
needs to be ex-
changed.
Ultra capacitor
Exchange is unneces-
sary although retention
time is about three
weeks.
Charge to a capacitor is
performed by carrying
out a turning on elec-
tricity start.
When time is not correct by no turning
on electricity for a long period of time,
the right time is set up on F2 screen.
Due to battery exchange was not
needs, the necessity for maintenances
other than failure is not need.
2
Production
quantity man-
agement
with functional
Function deleted.
A time setup was added to the portion
which the screen (F2) of production
control deleted.
3 DCDT Power
±15V
±10Vref
The power supply for
DCDT was changed into
the stabilized power
supply of ±10V.
It changed for stabilization of the
power supply for sensors of a core
position.
Moreover, it was referred to as ±10V
so that it might be united with an input
range.
The method of wiring changes.
Please refer to
Figure 1-19 TB-1 Con-
nections
in Page 21.