© MOOG 2010
This document is subject to MOOG INTELLECTUAL AND PROPRIETARY INFORMATION LEGEND . The details are on page II.
52
MRJ04410
Figure 2-8 Profile Mode Screen
2-4-2.
F1: Profile Mode
Mode obtained by pressing the F1 Key.
Display
Normally displayed when manufacturing containers.
Profile Mode Function Items
Please refer to
Figure 2-8
and
Figure 2-13
for further
definition information.
Die Gap Opening Profile
The profile uses 100 separate points to define the desired
parison wall thickness profile. The horizontal axis of the LCD
display is the programmed tooling die gap or parison wall
thickness. The points along the vertical axis of the LCD dis-
play are Shot Size, either cycle time or accumulator stroke.
Linear or Spline interpolation can be set at machine setup
display (F4+Set) is used to define the profile between the
operator set points. *
Figure 2-8
showing Spline type.
Each profile point may be set to a value between 0% to 100% of the maximum tooling die gap opening by
rotating the Entry Knob and pressing Set.
As shown in
Figure 2-8
, the active profile point on the display is indicated by a inverse video bar. Its value
is shown on the upper right hand corner of the LCD display as “DATA…%”(79.0% on
Figure 2-8
). Points
displayed as “*” are interpolated values. If the value not displayed “*” its settled program point, you can
also see setting point with purple color line mark on profile left side as shown
Figure 2-8
.
If “-“ is being displayed as a point value of left side of profile, that value has been set using F2: Marker
Mode.
To cancel entered profile points, turn the Entry Knob counterclockwise until the display in the upper right
hand corner of the LCD display indicates “DATA: ---.-“ and press the Set Key.
The scale of the profile display will automatically change between 25%, 50%, 75% and 100% as required.
The following Function Items are found in the area of the LCD display above the parison profile.
Point No.
If the cursor placed on this value, the profile bar in the graph can be moved up and down by turn the Entry
Knob, CW to move up and CCW to move down. Once decided cursor point on profile graph press Set key,
and cursor move to Data value.