2-4.
THE SCREENS
Programmed Parison Wall Thickness
Die Gap Opening – 100% max.
Figure 2-7 F1: Profile mode Screen
2-4-1.
INPUT METHOD
The Cursor key is used to move the cursor to each displayed function item. The Cursor will indicate its
location by light green on LCD display. If the cursor put on to Point No. the cursor in Profile graph will move
by rotating the Entry Knob (Clockwise to up, Counterclockwise to down; X10 key makes the Entry Knob
faster) to obtain the desired value, then confirm the value by pressing the Set key. And, If the cursor put on
to Data, the cursor in Profile graph will move by rotating the Entry Knob (Clockwise to increase, Coun-
terclockwise to decrease; X10 key makes the Entry Knob faster) to obtain the desired value, then confirm
the value by pressing the Set key.
Any item value changed and not confirmed with the Set key will not be changed when the Cursor is
moved to the next point. If set values are modified, changes take effect during the next machine
cycle.
Container Identification
100 Program Point
= Parison Top
First Program Point
= Parison Bottom
Programmed Parison
Wall Thickness or Die
Gap Opening at Length
Point 80
Date and Time
Indicate actual line from
DCDT feed Back. And
Indicate process of run-
ning.
Selectable indication ON
or OFF at setup display
(F4+Set). See 1-7-2.
Program setting Point
Indicator