MRJ04410
00h : MFB valve current
-> Monitored MFB Servovalve Current (Set at F4+Set) with +-10V.
01h : EFB spool monitor
-> Monitored Spool position (4-20mA) with +-10V if EFB mode.
02h : DCDT input voltage
-> Monitored DCDT Position (0-100%) with 0-10V.
03h : Accumulator voltage
-> Monitored Accumulator Position (0-100%) with 0-10V.
04h : Position command
-> Monitored Parison command signal with 0-10V.
Offset
Add this value to output signal of monitor channel.
Gain
Set gain function for output signal. Ex) if Gain=2.00 then 50% is 10V output.
2-4-9.
F3+Set File delete and Backup/Restore
Mode is obtained by pressing F3+Set.
Display
Not Available while manufacturing containers
Function
Data file delete and all data backup to SD card and Restore
from SD card
Commands
Select the required function “Delete”, ”Backup” or “Re-
store” using the Entry Knob and confirm with the Set Key.
Delete
Delete the existing file which saved in Flash RAM. (F3: File
mode). If press Set at Delete, Display indicate as
Figure
2-33
. And select file name using Entry Knob and press Set.
Then will be delete the selected file.
Backup
If press Set at Backup, all Flash RAM data in DigiPackⅡis copied in to SD card.
* This function backup Profile data only, dose not managed Wave data.