5 MONITORING
5.1 Explanation of monitor signals
319
5
Fully closed loop control [G] [WG]
This control can be used on servo amplifiers with firmware version A5 or later.
PWM
+
M
+
-
-
+
-
+
+
+
-
+
-
+
-
+
-
+
-
+
FBD
FBN
Droop pulses
Speed command
output 1
Position
control
Speed
control
Current
control
Current command
Bus voltage
Speed
command
Current
detector
Servo
motor
Encoder
Current feedback
Position feedback
Fully closed
Semi closed
Differentiation
Differentiation
Differentiation
Internal temperature
of encoder
Load-side
encoder
Servo motor
speed
Torque
Motor/load side speed
deviation
Motor/load side speed
deviation
Speed command
output 2
Position
command
Differentiation
Dual filter
Servo motor-side
droop pulses
Load-side droop
pulses
Servo motor-side feedback pulse
Load-side feedback pulse
(load-side resolution unit)