116
3 BASIC FUNCTION
3.11 In-position range setting
Setting method [G] [WG]
The servo parameters related to the in-position setting are as follows.
Setting method [A]
The servo parameters related to the in-position setting are as follows.
Servo
parameter
Symbol
Name
Outline
PA10
INP
In-position range
Set the in-position range.
Initial value: 25600 [pulse]
PC06.0
*COP3
In-position range unit selection
Select a unit of the in-position range.
0: Command input pulse unit (initial value)
1: Servo motor encoder pulse unit
PD13.2
*DOP2
INP output signal ON condition
selection
Select the in-position on condition.
0: Within the in-position range (initial value)
1: Within the in-position range and at the completion of command output
2: Within the in-position range, at the completion of command output, and at start
signal off
Servo
parameter
Symbol
Name
Outline
PA10
INP
In-position range
Set the in-position range.
Initial value: 400 [pulse]
PC24.0
*COP3
In-position range unit selection
Select a unit of the in-position range.
0: Command input pulse unit (initial value)
1: Servo motor encoder pulse unit
PD31.2
*DOP2
INP output signal ON condition
selection
Select the in-position on condition.
0: Within the in-position range (initial value)
1: Within the in-position range and at the completion of command output
2: Within the in-position range, at the completion of command output, and at start
signal off