156
4 APPLICABLE FUNCTIONS
4.1 Tough drive function
Timing chart
■
When the instantaneous power failure time of the control circuit power supply > [Pr. PF25
SEMI-F47 function - Instantaneous power failure detection time (instantaneous power failure
tough drive - Detection time)]
The alarm occurs when the instantaneous power failure time of the control circuit power supply exceeds [Pr. PF25 SEMI-F47
function - Instantaneous power failure detection time (instantaneous power failure tough drive - Detection time)]. MTTR
(During tough drive) turns on after the instantaneous power failure is detected.
MBR (Electromagnetic brake interlock) turns off when the alarm occurs.
*1 For the undervoltage level, refer to the following table.
[Pr. PF25]
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Instantaneous power failure time of control circuit power supply
Control circuit
power supply
Bus voltage
Undervoltage level
*1
Base circuit
ALM
(Malfunction)
MTTR
(During tough drive)
MBR
(Electromagnetic
brake interlock)
WNG
(Warning)