4 APPLICABLE FUNCTIONS
4.6 Drive recorder
263
4
Waveform recording inapplicable alarm list
Alarms that are not covered in the alarm history are not subject to recording by the drive recorder. For details, refer to the
following manual.
MR-J5 User's Manual (Troubleshooting)
The alarms shown in the following table are saved in the alarm history, but are not subject to recording by the drive recorder.
The drive recorder does not operate in this case.
In addition, data may not be recorded when the following alarms occur depending on the circumstances of the alarm
occurrence.
Alarm No.
Name
010.1
Voltage drop in the control circuit power
012
Memory error 1
016
Encoder initial communication error 1
017
Board error
019
Memory error 3
01A
Servo motor combination error
01E
Encoder initial communication error 2
01F
Encoder initial communication error 3
025
Absolute position erased
119
Memory error 4
Alarm No.
Name
013
CPU error
014
Control process error