3 BASIC FUNCTION
3.16 Electromagnetic brake interlock function
139
3
■
Ready-off command from controller [G] [WG]
After the base circuit is turned off with the ready-off command, the servo motor is stopped with the dynamic brake and
electromagnetic brake.
*1 ON: Electromagnetic brake is not activated
OFF: Electromagnetic brake is activated
When the forced stop deceleration function is not used
When [Pr. PA04.3 Forced stop deceleration function selection] is set to "0" (Forced stop deceleration function
disabled).
■
Turning the servo-on command on/off [G] [WG]
Page 133 Turning the servo-on command on/off [G] [WG]
■
Turning the servo-on command on/off [A]
Page 134 Turning the servo-on command on/off [A]
■
Turning the quick stop command (from controller) or EM1 (Forced stop 1) on/off
When the off command is inputted, the servo motor is stopped with the dynamic brake and electromagnetic brake.
*1 ON: Electromagnetic brake is not activated
OFF: Electromagnetic brake is activated
ON
OFF
ON
OFF
ON
OFF
0 r/min
(10 ms)
OFF
*1
Dynamic brake
Dynamic brake
+ electromagnetic brake
Servo motor speed
Electromagnetic brake
Base circuit
Operation delay time of
electromagnetic brake
Ready-on command
(from controller)
MBR
(Electromagnetic
brake interlock)
ON
OFF
0 r/min
ON
OFF
*1
(10 ms)
(210 ms)
(210 ms)
(ON)
(OFF)
Dynamic brake
Dynamic brake
+ electromagnetic brake
Servo motor speed
Electromagnetic brake
released
Electromagnetic brake
Base circuit
Operation delay time
of electromagnetic
brake
Disabled
Quick stop command
(from controller) or EM1
(Forced stop 1)
Enabled
MBR
(Electromagnetic
brake interlock)