8 COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC AC SERVO PROTOCOL) [A]
8.5 Detailed explanations of commands
429
8
Output signal pin on/off (output signal (DO) forced output)
In the test operation mode, the output signal pins can be turned on/off regardless of the servo status. Use the command [9] [0]
to disable external input signals in advance.
Selecting the output signal (DO) forced output of the test operation mode
Transmit the command [8] [B] + data No. [0] [0] + data "0004" to select the output signal (DO) forced output.
External output signal on/off
Transmit the following communication command.
Output signal (DO) forced output
To stop the output signal (DO) forced output, transmit the command [8] [B] + data No. [0] [0] + data.
Command
Data No.
Setting data
[9] [2]
[A] [0]
See below.
Bit
CN3 connector pin
Bit
CN3 connector pin
Bit
CN3 connector pin
Bit
CN3 connector pin
0
49
8
14
16
24
1
24
9
17
25
2
23
10
18
26
3
25
11
19
27
4
22
12
20
28
5
48
13
21
29
6
33
14
22
30
7
13
15
23
31
Command
Data No.
Transmission
data
Selecting test operation mode
[8] [B]
[0] [0]
0000
Test operation mode cancel
0 4
0
0
0
0
0
0
Selection of test operation mode
4: Output signal (DO) forced output
b31
b1b0
1: On
0: Off
Each bit command is transmitted to the master station as hexadecimal data.