1 FUNCTION
1.1 Function explanation
15
1
Protective functions
*1 "Ver." indicates the supported firmware version of the servo amplifier. The functions are available on servo amplifiers with the indicated
firmware version or later.
Functions
Detailed functions
Description
Ver.
MR-J5
Detailed explanation
G
A
Alarm
Alarm function
This function displays an alarm or warning when an
error occurs during operation. When an alarm occurs,
ALM (Malfunction) turns off and stops the servo motor.
When a warning occurs, WNG (Warning) will turn on.
The servo motor may stop or continue operation
depending on the warning.
A0
A0
Alarm history clear
This function clears alarm histories.
A0
A0
Power error
detection
Disconnection detection function
This function detects a disconnection in the main
circuit power supply input and the servo motor power
supply output.
A0
A0
Disconnection/incorrect
wiring detection function
Coasting distance
reduction
Forced stop deceleration function
This function decelerates the servo motor to a stop at
EM2 (Forced stop 2) off or when there is an alarm.
A0
A0
Drop protection
Electromagnetic brake interlock
function
This function operates the electromagnetic brake at
servo off and error occurrence, and prevents the
vertical axis from dropping.
A0
A0
Electromagnetic brake
interlock function
Vertical axis freefall prevention
function
This function moves the axis up by the mechanical
backlash amount of the electromagnetic brake to
prevent damage to machines.
A0
A0