2 CONTROL MODE
2.2 Control mode [A]
81
2
Speed limit in torque control mode
■
Speed limit value and speed
The speed is limited to the limit value of the servo parameter or the value set in the applied voltage of VLA (Analog speed
limit).
A relation between the VLA (Analog speed limit) applied voltage and the limit value is the same as the specification in the
section of the torque control mode.
Page 76 Speed limit value and speed
■
Speed limit value selection
The speed limit can be selected with SP1 (Speed selection 1).
*1 0: OFF
1: ON
The speed can also be switched during operation. Acceleration/deceleration is performed with the time constant setting in [Pr.
PC01 Speed acceleration time constant] and [Pr. PC02 Speed deceleration time constant].
When the internal speed 1 is used to command a speed, the speed does not vary with the ambient temperature.
■
VLC (Limiting speed)
The specifications are the same as those described in the section for the torque control mode.
Torque control and torque limit in torque control mode
The specifications are the same as those described in the section for the torque control mode.
Input device
Speed limit value
SP1
0
VLA (Analog speed limit)
1
[Pr. PC05 Internal speed 1]