408
8 COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC AC SERVO PROTOCOL) [A]
8.4 Command and data No. list
Servo parameters (commands [0] [4]/[1] [5]/[1] [6]/[1] [7]/[0] [8]/[0] [9])
External I/O signals (command [1] [2])
Command
Data No.
Description
Frame
length
[0] [4]
[0] [1]
Reading a servo parameter group
0000: Basic setting servo parameters ([Pr. PA_ _ ])
0001: Gain/filter servo parameters ([Pr. PB_ _ ])
0002: Extension setting servo parameters ([Pr. PC_ _ ])
0003: I/O setting servo parameters ([Pr. PD_ _ ])
0004: Extension setting 2 servo parameters ([Pr. PE_ _ ])
0005: Extension setting 3 servo parameters ([Pr. PF_ _ ])
000B: Motor extension setting servo parameters ([Pr. PL_ _ ])
4
[1] [5]
[0] [1] to [F] [F]
Current values of servo parameters
The current values of the parameters in the servo parameter group specified with the command [8]
[5] + data No. [0] [0] can be read. Always specify a servo parameter group with the command [8] [5]
+ data No. [0] [0] before reading the current values.
The decimal converted from the data No. value (hexadecimal) corresponds to the servo parameter
No.
12
[1] [6]
[0] [1] to [F] [F]
Upper limit value of each servo parameter setting range
The permissible upper limit values of the parameters in the servo parameter group specified with
the command [8] [5] + data No. [0] [0] can be read. Always specify a servo parameter group with
the command [8] [5] + data No. [0] [0] before reading the upper limit values.
The decimal converted from the data No. value (hexadecimal) corresponds to the servo parameter
No.
12
[1] [7]
[0] [1] to [F] [F]
Lower limit value of each servo parameter setting range
The permissible lower limit values of the parameters in the servo parameter group specified with
the command [8] [5] + data No. [0] [0] can be read. Always specify a servo parameter group with
the command [8] [5] + data No. [0] [0] before reading the lower limit values.
The decimal converted from the data No. value (hexadecimal) corresponds to the servo parameter
No.
12
[0] [8]
[0] [1] to [F] [F]
Servo parameter symbols
The symbol of the parameters in the servo parameter group specified with the command [8] [5] +
data No. [0] [0] can be read. Always specify a servo parameter group with the command [8] [5] +
data No. [0] [0] before reading the symbol.
The decimal converted from the data No. value (hexadecimal) corresponds to the servo parameter
No.
12
[0] [9]
[0] [1] to [F] [F]
Servo parameters writable/not writable
Whether the parameters in the servo parameter group specified with the command [8] [5] + data
No. [0] [0] are writable can be read. Always specify a servo parameter group with the command [8]
[5] + data No. [0] [0] before reading whether the parameters are writable.
0000: Writable
0001: Not writable
4
Command
Data No.
Description
Frame
length
[1] [2]
[0] [0]
Input device status
8
[4] [0]
External input pin status
[6] [0]
Status of input devices switched on via communication
[8] [0]
Output device status
[C] [0]
External output pin status