6 FUNCTIONAL SAFETY
6.4 Safety sub-function
347
6
Output device
■
Outline
The output device of the status monitor function (SM) has the following characteristics.
• Output device selection
A device can be freely assigned to the output signal of the CN8-6/CN8-7 pin by parameter.
• Duplication of output
The same signal is duplicated for output with duplicated wiring. As a result, even if an error occurs in one of the output
devices, the functionality will not be lost.
• Diagnosis with test pulses
Failure diagnosis including external wiring is performed by sending pulse signals that are temporarily turned off when the
output signals are on.
Enabled/disabled can be selected with [Pr. PSD29 Output device - Test pulse diagnosis execution selection].
■
Output device selection
Select the output device to be assigned to the output signal of the CN8-6/CN8-7 pin with [Pr. PSD08 Output device selection
DO1].
For details on each output device, refer to the items in the following table. For multi-axis servo amplifiers, axes for outputs can
be selected from any of the following: The A-axis only, or the A, B, and C-axes as an AND output.
CN8 pin No.
Parameter
6
[Pr. PSD08 Output device selection DO1]
7
Output signal
Reference
STOS (STO output)
SS1S (SS1 output)
SS2S (SS2 output)
SLS1S (SLS1 output)
SLS2S (SLS2 output)
SLS3S (SLS3 output)
SLS4S (SLS4 output)
SSMS (SSM output)
SOSS (SOS output)
SBCS (SBC output)
SDIPS (SDIP output)
SDINS (SDIN output)
SLIS (SLI output)
SLT1S (SLT1 output)
SLT2S (SLT2 output)
SLT3S (SLT3 output)
SLT4S (SLT4 output)