428
8 COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC AC SERVO PROTOCOL) [A]
8.5 Detailed explanations of commands
■
Temporary stop/restart/remaining distance clear
Transmitting the following command, data No., and data during positioning operation will decelerate the servo motor to a stop.
Transmitting the following command, data No., and data during a temporary stop will restart the servo motor.
*1 "_" indicates a blank.
Transmitting the following command, data No., and data during a temporary stop will stop positioning operation and erase the
remaining travel distance.
*1 "_" indicates a blank.
Command
Data No.
Data
[A] [0]
[4] [1]
STOP
Command
Data No.
[A] [0]
[4] [1]
GO _ _
Command
Data No.
[A] [0]
[4] [1]
CLR _