4 APPLICABLE FUNCTIONS
4.5 Machine diagnosis
205
4
Related objects [G] [WG]
For details on the objects, refer to the User's Manual (Object Dictionary).
index
Sub
Object
Name
Description
2C29h
0
VAR
Fault prediction status
[Bit 0 to 3: Friction failure prediction status]
0: Friction failure prediction disabled
1: During preparation for friction failure prediction
2: During execution of friction failure prediction
3: During friction failure prediction warning
[Bit 4 to 7: Vibration failure prediction status]
0: Vibration failure prediction disabled
1: During preparation for vibration failure prediction
2: During execution of vibration failure prediction
3: During vibration failure prediction warning
[Bit 8 to 11: Total travel distance failure prediction status]
0: Motor total travel distance failure prediction disabled
1: Motor total travel distance failure prediction being executed
2: Motor total travel distance failure prediction at warning
[Bit 12 to 15: Motor total travel distance calculation status]
0: During stop of motor total travel distance calculation
1: During calculation of motor total travel distance
[Bit 16 to 19: reserved]
[Bit 20 to 23: Static friction failure prediction status]
0: Static friction failure prediction disabled
1: During preparation for static friction failure prediction
2: During execution of static friction failure prediction
3: During static friction failure prediction warning
[Bit 24 to 27: Belt tension deterioration prediction status]
0: Belt tension deterioration prediction disabled
1: Belt tension deterioration prediction in progress
2: During belt tension deterioration warning
[Bit 28 to 31: Belt tension estimation status]
0: Belt tension estimation in progress
1: Belt tension estimation has finished
7: Belt tension estimation is not set
2C2Dh
0
VAR
Vibration based fault prediction
threshold
Vibration failure prediction - Threshold
The threshold used for vibration failure prediction is displayed in
increments of 0.1 % in relation to the rated torque as 100 %.
2C2Eh
0
VAR
Vibration based fault prediction
prepare status
Vibration failure prediction - Preparation progress
The threshold creation progress used for vibration failure prediction is
displayed as a percentage. The creation of a threshold for vibration
failure prediction finishes at 100 %.