4 APPLICABLE FUNCTIONS
4.13 A/B/Z-phase pulse output function
■
When [Pr. PC03.2] = "1" (load-side encoder)
Encoder output pulse phase selection
Set [Pr. PC03.0 Encoder output pulse - Phase selection].
Setting value of [Pr. PC03.1]
When in the fully closed loop control mode
When the scale measurement function is
enabled
"0" (output pulse setting)
[AL. 037] occurs.
"1" (dividing ratio setting)
Set the dividing ratio to the resolution per servo motor
revolution with [Pr. PA15 Encoder output pulses].
Set the dividing ratio to the travel distance of the scale
measurement encoder with [Pr. PA15 Encoder output
pulses].
"3" (A-phase/B-phase pulse
electronic gear setting)
Set the A-phase/B-phase pulse electronic gear with [Pr.
PA15 Encoder output pulses] and [Pr. PA16 Encoder
output pulses 2].
Set the A-phase/B-phase pulse electronic gear with [Pr.
PA15 Encoder output pulses] and [Pr. PA16 Encoder
output pulses 2].
"4" (A/B-phase pulse through output
setting)
• A/B-phase pulses of the A/B/Z-phase differential output
type encoder are outputted.
• This is enabled only when an A/B/Z-phase differential
output type encoder is used.
If a different encoder is connected, [AL. 037] occurs.
• Output pulse = A/B-phase pulse of A/B/Z-phase
differential output type encoder [pulse]
The setting of [Pr. PC03.0 Encoder output pulse - Phase
selection] is not used.
The settings of [Pr. PA15 Encoder output pulses] and [Pr.
PA16 Encoder output pulses 2] are not used.
• A/B-phase pulses of the A/B/Z-phase differential output
type encoder are outputted.
• This is enabled only when an A/B/Z-phase differential
output type encoder is used.
If a different encoder is connected, [AL. 037] occurs.
A/B/Z-phase differential output type encoders cannot be
used in the linear servo motor control mode or the direct
drive motor control mode.
• Output pulse = A/B-phase pulse of A/B/Z-phase
differential output type encoder [pulse]
The setting of [Pr. PC03.0 Encoder output pulse - Phase
selection] is not used.
The settings of [Pr. PA15 Encoder output pulses] and [Pr.
PA16 Encoder output pulses 2] are not used.
Setting value of [Pr. PC03.0]
Servo motor rotation direction/linear servo motor travel direction
CCW or positive direction
CW or negative direction
0: Increasing A-phase 90° in CCW or positive direction
1: Increasing A-phase 90° in CW or negative direction
Output pulse =
Resolution per revolution
Setting value of [Pr. PA15]
[pulse/rev]
Output pulse =
Travel distance of scale measurement encoder
Setting value of [Pr. PA15]
[pulse]
Output pulse =
Resolution per revolution ×
Setting value of [Pr. PA16]
Setting value of [Pr. PA15]
[pulse/rev]
Output pulse =
Travel distance of scale
measurement encoder
×
Setting value of [Pr. PA16]
Setting value of [Pr. PA15]
[pulse]
A-phase
B-phase
A-phase
B-phase
A-phase
B-phase
A-phase
B-phase