4 APPLICABLE FUNCTIONS
4.6 Drive recorder
257
4
*1 Available on servo amplifiers with firmware version A5 or later.
8000
RD
Ready
DO
8001
SA
Speed reached
8002
ZSP
Zero speed detection
8003
TLC
Limiting torque
8004
VLC
Limiting speed
8005
INP
In-position
8007
WNG
Warning
8008
ALM
Malfunction
8009
OP
Z-phase output
800A
MBR
Electromagnetic brake interlock
800B
DB
External dynamic brake
800F
BWNG
Battery warning
8010
ALM2
Malfunction 2
8015
STO
In STO state
8016
SMPD
Magnetic pole detection completion
8018
CDPS2
Variable gain enabled 2
8019
CDPS
Variable gain enabled
CLDS
Fully closed loop control in progress
801B
ABSV
Absolute position erased
801D
IPF
Instantaneous power failure
801E
SPC
Under proportional control
801F
MTTR
During tough drive
8020
ABSB0
ABS transmission data Bit0
8021
ABSB1
ABS transmission data Bit1
8022
ABST
ABS transmission data ready
8051
ALMWNG
Malfunction/Warning
8052
BW9F
AL9F warning
Setting value
Symbol
Name
Classification