Parameter list
Parameter list
64
Parameter List
Electr
onic ther
mal
O/L
rel
a
y
600
Free thermal reduction speed 1
0 to 12000r/min/
0 to 8000r/min
1r/min
9999
600
00
80
6
601
Free thermal reduction ratio 1
1 to 100%
1%
100%
601
01
81
6
602
Free thermal reduction speed 2
0 to 12000r/min/
0 to 8000r/min
1r/min
9999
602
02
82
6
603
Free thermal reduction ratio 2
1 to 100%
1%
100%
603
03
83
6
604
Free thermal reduction speed 3
0 to 12000r/min/
0 to 8000r/min
1r/min
9999
604
04
84
5
—
643
Voltage compensation amount setting
0 to 150%, 9999
1%
9999
643
2B
AB
6
—
658
Wiring resistance
0 to 5
, 9999
0.001
9999
658
3A
BA
6
—
665
Regeneration avoidance speed gain
0 to 200%
0.1%
100%
665
41
C1
6
Adjustment
function
672
Lq tuning target current adjustment
coefficient
50 to 150%, 9999
0.1%
9999
48
C8
6
702
Maximum motor speed
0 to 6000r/min/
0 to 4000r/min
1r/min
9999
702
02
82
7
706
Induced voltage constant (phi f)
0 to 5000mV/(s/rad),
9999
0.1mV/(s/rad)
9999
706
06
86
7
707
Motor inertia (integer)
10 to 999, 9999
1
9999
707
07
87
7
711
Motor Ld decay ratio
0 to 100%, 9999
0.1%
9999
711
0B
8B
7
712
Motor Lq decay ratio
0 to 100%, 9999
0.1%
9999
712
0C
8C
7
717
Starting resistance tuning
compensation
0 to 200%, 9999
0.1%
9999
11
91
7
721
Starting magnetic pole position
detection pulse width
0 to 6000
μ
s, 9999
0.1
μ
s
9999
721
15
95
7
724
Motor inertia (exponent)
4 to 7, 9999
1
9999
18
98
7
725
Motor protection current level
0 to 500%, 9999
0.1%
9999
725
19
99
7
726
Motor induced voltage constant (phi f)
exponent
0 to 2, 9999
1
9999
726
1A
9A
7
—
736
Electromagnetic brake interlock time
0 to 1s
0.01s
0s
736
56
D6
7
—
779
Operation speed during
communication error
0 to 12000/min/
0 to 8000r/min
, 9999
1r/min
9999
779
4F
CF
7
—
785
PM control torque boost
0 to 150%, 9999
0.1%
9999
785
55
D5
7
Acceleration/
deceleration
time
791
Acceleration time in low-speed range
0 to 3600s, 9999
0.1s
9999
791
5B
DB
7
792
Deceleration time in low-speed range
0 to 3600s, 9999
0.1s
9999
792
5C
DC
7
—
795
DC brake torque boost
0 to 150%, 9999
0.1%
9999
795
5F
DF
7
—
799
Pulse increment setting for output
power
0.1kWh, 1kWh, 10kWh,
100kWh, 1000kWh
0.1kWh
1kWh
799
63
E3
7
—
800
Control method selection
9, 30
1
30
800
00
80
8
Adjus
tmen
t
functio
n
820
Speed control P gain
0 to 1000%
1%
15%
820
14
94
8
821
Speed control integral time
0 to 20s
0.001s
0.333s
821
15
95
8
824
Torque control P gain (current loop
proportional gain)
0 to 200%, 9999
1%
9999
824
18
98
8
825
Torque control integral time (current
loop integral time)
0 to 500ms, 9999
0.1ms
9999
825
19
99
8
—
859
Rated PM motor current
0 to 500A, 9999
0.01A
9999
859
3B
BB
8
—
870
Speed detection hysteresis
0 to 150r/min/
0 to 100r/min
1r/min
15r/min
870
46
C6
8
Protecti
ve
functions
872
Input phase loss protection selection
0, 1
1
0
872
48
C8
8
Function
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Remarks
Instruction Code
Parameter
Read
Write
Extended
Copy
Clear
All Clear
Содержание FR-D720-0.2K-G
Страница 45: ...34 MEMO ...
Страница 293: ...290 MEMO ...
Страница 294: ...291 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...