28
Connection of stand-alone option unit
It is recommended to configure a sequence, which shuts off power in the input side of the drive unit by the external thermal
relay as shown below, to prevent overheat and burnout of the brake resistor (MRS type, MYS type) and high duty brake
resistor (FR-ABR) in case the regenerative brake transistor is damaged. (The brake resistor cannot be connected to the
0.2K.)
Refer to the table below for the type number of each capacity of thermal relay and the diagram below for the connection.
When the power supply is 400V class, install a step-down transformer.
Power
Supply
Voltage
Brake Resistor
Thermal Relay Type
(Mitsubishi Electric
product)
Rated Operating Current
200V
MRS120W200
TH-T25-0.7A
120VAC: 2A (NO contact) /
3A (NC contact),
240VAC: 1A (NO contact) /
2A (NC contact) (AC15 class)
110VDC: 0.2A,
220VDC: 0.1A (DC13 class)
MRS120W100
TH-T25-1.3A
MRS120W60
TH-T25-2.1A
MRS120W40
TH-T25-3.6A
MYS220W50
(two units in parallel)
TH-T25-5A
Power
Supply
Voltage
High-duty
Brake Resistor
Thermal Relay Type
(Mitsubishi Electric
product)
Rated Operating Current
200V
FR-ABR-0.4K
TH-T25-0.7A
120VAC: 2A (NO contact) /
3A (NC contact),
240VAC: 1A (NO contact) /
2A (NC contact) (AC15 class)
110VDC: 0.2A,
220VDC: 0.1A (DC13 class)
FR-ABR-0.75K
TH-T25-1.3A
FR-ABR-2.2K
TH-T25-2.1A
FR-ABR-3.7K
TH-T25-3.6A
400V
FR-ABR-H0.4K
TH-T25-0.24A
FR-ABR-H0.75K
TH-T25-0.35A
FR-ABR-H1.5K
TH-T25-0.9A
FR-ABR-H2.2K
TH-T25-1.3A
FR-ABR-H3.7K
TH-T25-2.1A
NOTE
The brake resistor connected should only be the dedicated brake resistor.
Brake resistor cannot be used with the brake unit, high power factor converter, power supply regeneration converter,
etc.
Do not use the brake resistor (MRS type, MYS type) with a lead wire extended.
Do not connect a resistor directly to terminals P/+ and N/-. This could cause a fire.
Parameters referred to
Pr. 30 Regenerative function selection
Refer to page 114.
MC
Drive unit
MC
R
PR
P/+
Thermal relay
(OCR)(
∗1
)
S/L2
T/L3
R/L1
ON
OFF
OCR
Contact
Power
supply
F
<Example 1>
MC
High-duty brake
resistor (FR-ABR)
T
∗2
Drive unit
MC
R
PR
P/+
Thermal relay
(OCR)(
∗1
)
S/L2
T/L3
R/L1
ON
OFF
B
C
OCR
Contact
Power
supply
F
<Example 2>
MC
MC
High-duty brake
resistor (FR-ABR)
T
∗2
1/L
1
5/L
3
2/T
1
6/T
3
To the drive unit
terminal P/+