284
Rating
7.1 Rating
Three-phase 200V power supply
Three-phase 400V power supply
The rated output capacity assumes the following output voltages: 230V for three-phase 200V, and 440V for three-phase 400V.
The power supply capacity varies with the value of the power supply side drive unit impedance (including those of the input reactor and cables).
Model FR-D720-
K-G
0.2
0.4
0.75
1.5
2.2
3.7
Out
put
Rated capacity (kVA)
0.3
0.6
1.0
1.7
2.8
4.0
Rated current (A)
1.4
2.5
4.2
7.0
10.0
16.5
Overload current rating
150% 60s, 200% 0.5s (Rated motor current, inverse-time characteristics)
Pow
er supply
Rated input AC voltage/frequency
Three-phase 200 to 240V 50Hz/60Hz
Permissible AC voltage fluctuation
170 to 264V 50Hz/60Hz
Permissible frequency fluctuation
±5%
Power supply capacity (kVA)
0.4
0.7
1.2
2.1
4.0
5.5
Protective structure (JEM1030)
Enclosed type (IP20)
Cooling system
Self-cooling
Forced air cooling
Approximate mass (kg)
0.5
0.8
1.0
1.4
1.4
1.8
Model FR-D740-
K-G
0.4
0.75
1.5
2.2
3.7
Output
Rated capacity (kVA)
0.4
0.9
1.7
2.7
3.8
Rated current (A)
1.2
2.2
3.6
5.0
8.0
Overload current rating
150% 60s, 200% 0.5s (Rated motor current, inverse-time characteristics)
Power s
up
pl
y
Rated input AC voltage/frequency
Three-phase 380 to 480V 50Hz/60Hz
Permissible AC voltage fluctuation
325 to 528V 50Hz/60Hz
Permissible frequency fluctuation
±5%
Power supply capacity (kVA)
0.9
1.5
2.5
5.5
9.5
Protective structure (JEM1030)
Enclosed type (IP20)
Cooling system
Natural
Forced air
Approximate mass (kg)
1.3
1.3
1.4
1.5
1.5