78
Test operation and gain adjustment of the PM sensorless vector control
(2) Valid/invalid statuses of I/O terminal functions during the test operation
1)
Input terminal function selection (Pr. 178 to Pr. 182)
All assignable functions are valid.
2)
Output terminal function selection (Pr. 190, Pr. 192)
Some functions have restrictions. For details, refer to the table below.
: Valid,
: Not output as there is no output current
(3) Valid/invalid statuses of monitor outputs during the test operation
: Valid,
: Invalid (always displays 0)
: Displays accumulated value before the test,
: Not monitored
Parameters referred to
Pr. 52 DU/PU main display data selection
Pr. 190, Pr. 192 (Output terminal function selection)
Signal
Name
Function
RUN
Drive unit running
SU
Up to speed
OL
Overload alarm
FU
Rotation speed detection
RBP
Regenerative brake pre-alarm
THP
Electronic thermal O/L relay pre-alarm
RY
Drive unit operation ready
Y12
Output current detection
Y13
Zero current detection
FDN
PID lower limit
FUP
PID upper limit
RL
PID forward/reverse rotation output
BOF
Brake opening request
MBR
Electromagnetic brake interlock
FAN
Fan fault output
FIN
Heatsink overheat pre-alarm
RY2
Operation ready 2
RY3
Operation ready 3
PID
During PID control activated
Y48
PID deviation limit
Y64
During retry
SLEEP PID output interruption
Y79
Pulse train output of output power
Y90
Life alarm
Y91
Fault output 3 (power-off signal)
Y92
Energy saving average value updated timing
Y93
Current average value monitor signal
Y95
Maintenance timer signal
REM
Remote output
LF
Alarm output
ALM
Fault output
9999
No function
Signal
Name
Function
*1
Monitor output is valid or invalid depending on the monitor type
(operation panel display, parameter unit display, or terminal FM/
AM). For details,
refer to page 134
*2
When the operation is switched to the test operation, "0" is
displayed. When the PM sensorless vector control is selected
again after a test operation, the following monitored items from the
last operation are displayed: output current peak value, motor
thermal load factor, drive unit thermal load factor, and the electronic
thermal relay load factor.
Monitoring Items
Operation
Panel/PU
Monitor
Display
FM
Output
Rotation speed
Output current
Output voltage
Fault display
Speed setting value
Converter output voltage
Regenerative brake duty
Electronic thermal relay load factor
*2
*2
Output current peak value
*2
*2
Converter output voltage peak value
Output power
Cumulative energization time
Reference voltage output
Actual operation time
Motor load factor
Cumulative power
PID set point
PID measured value
PID deviation
Input terminal status
/
Output terminal status
/
Drive unit I/O terminal monitor
/
Motor thermal load factor
*2
*2
Drive unit thermal load factor
*2
*2
PTC thermistor resistance
Monitoring Items
Operation
Panel/PU
Monitor
Display
FM
Output