139
Monitor display and monitor output signal
4.12.3 Reference of the terminal FM (pulse train output) (Pr. 55, Pr. 56)
The pulse train output terminal FM is available for monitor output.
Set the reference of the signal output from terminal FM.
Parameter
Number
Name
Initial Value
Setting Range
Description
55
Speed monitoring
reference
3000 r/min
0 to 12000 r/min /
0 to 8000 r/min
Full-scale value when rotation speed monitor
value is output to terminal FM.
56
Current monitoring
reference
Rated motor
current
0 to 500A
Full-scale value when current monitor value is
output to terminal FM.
The above parameters can be set when
Pr. 160 Extended function display selection
=
"
0
"
.
The above parameters allow their settings to be changed during operation in any operation mode even if "0" (initial value) is set in
Pr. 77 Parameter write
selection
.
The value left of the slash is for the 2.2K drive unit or lower. The one right of the slash is for the 3.7K drive unit.
If a value exceeding the upper speed limit of the motor is set, the actual operation will be limited at the maximum rotation speed. The setting range is for
the S-PM motor. The maximum setting value differs depending on the number of poles of the applied motor.
Refer to page
for the rated motor current.
(1) Speed monitor reference
(Pr. 55)
Set the full scale value when outputting the speed monitor from terminal FM.
Set the speed when the optional speed meter (1mA analog meter), which is connected to the terminal FM and SD,
shows 1500 r/min or 3000 r/min (shows full scale).
Set the rotation speed (set speed) at which the pulse speed of the FM output is 1440 pulses/s.
The pulse speed and rotation speed are proportional to each other. (The maximum pulse train output is 2400 pulses/s.)
(2) Current monitor reference
(Pr. 56)
Set the full scale value when outputting the current monitor from terminal FM.
Set the output current at which the pulse speed of the FM output is 1440 pulses/s.
The pulse speed and output current monitor value are proportional to each other. (The maximum pulse train output is
2400 pulses/s.)
1500r/min
Rotation speed
3000r/min
(Initial value)
2400
1440
Setting range of
Pr. 55
Pulse speed
(pulses/s)
Rated current
(initial value)
500A
Setting range of
Pr. 56
Pulse speed
(pulses/s)
2400
1440