![Mitsubishi Electric FR-D720-0.2K-G Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/mitsubishi-electric/fr-d720-0-2k-g/fr-d720-0-2k-g_instruction-manual_239221089.webp)
86
Adjustment of the output torque (current) of the motor
4.5.2
Start torque adjustment (Pr. 785)
Use
Pr. 785
to set the maximum torque generated in the low-speed range lower than 10% of the rated speed.
Set a large value to generate a large starting torque.
Continuous operation at the rotation speed lower than 10% of the rated speed even with no load may cause the motor
overload trip fault (E.THM) depending on the operating time because a current flows regardless of load generation.
For continuous operation at the speed lower than 10% of the rated speed, set
Pr. 785
to the value shown in the following
table or lower.
In the low speed range lower than 10% of the rated speed,
Pr. 22 Stall prevention operation level
is disabled. Thus, a drive
unit failure, such as the overcurrent protection and the loss of synchronism detection, may occur when a torque equal to or
larger than the
Pr. 785 setting
is applied.
Reduction of the motor torque in the low-speed range lower than 10% of the rated speed can be improved.
Parameter
Number
Name
Initial Value
Setting Range
Description
785
PM control torque boost
9999
0 to 150%
Set the maximum torque generated in the
low-speed range lower than 10% of the rated
speed.
9999
Set as 100%
The above parameters can be set when
Pr. 160 Extended function display selection
= "0".
Motor
Drive Unit Model
PM Motor
Capacity
Pr. 785
Setting
S-PM geared motor
FR-D720-0.2K to 1.5K-G
0.1kW to 0.75kW
80% or less
FR-D720-2.2K to 3.7K-G
1.5kW to 2.2kW
50% or less
FR-D740-0.4K to 1.5K-G
0.2kW to 0.75kW
80% or less
FR-D740-2.2K to 3.7K-G
1.5kW to 2.2kW
50% or less
PM motors other than above
FR-D720-0.2K to 3.7K-G
FR-D740-0.4K to 3.7K-G
-
50% or less
NOTE
Keep the short-time torque to
Pr. 785
setting or lower.