Keyboard Section
Keyboard/Display Replacement
To remove the keyboard/display assembly from the cover, refer to Figure 2-1 and
the following procedure:
1. Turn OFF the power switch to the EMT 1 and remove the power cord from the
power source electrical outlet and the rear of the machine.
2. Remove the cable cover from the base plate at the rear of the keyboard/display
assembly.
3. Remove the cable strain relief plate from behind the keyboard/display assembly.
4. Remove the 4 screws from the base plate of the assembly to loosen the
keyboard/display assembly and cover.
5. Carefully slide the assembly forward until you can access the cables.
6. Pinch the locking lever of the small 2-wire connector and remove it from the
keyboard PCB.
7. Use a 3/16" nut driver and remove the 2 nuts securing the 15-pin connector to
the keyboard PCB.
Keyboard
Section
Figure 2 - 1
2 - 2
Keyboard Section
EMT 1 Technical Manual
Melco Embroidery Systems