Z Motor Replacement
Note:
This procedure requires a Gates 5M Tensiometer (Melco p/n 992165-01)
for proper belt adjustment after replacing the motor.
1. Turn the main power Off, and remove the power cord from power source.
2. Remove the rear head cover and the right rear table top which covers the
electronics section.
3. Disconnect the Z motor harness at the in-line connection going into the cable to
the electronics card cage connectors.
4. Using a properly sized open end wrench, loosen the two motor bracket
mounting/tensioning nuts. (See Figure 3-3) to take the tension off the belt.
Thread Saddle
front mounting
screws
Thread Saddle
rear mounting
screws
Figure 3 - 1
front mountings
for Thread Saddle
rear mountings
for Thread Saddle
Figure 3 - 2
Motor bracket
mounting/tensioning
nuts
Figure 3 - 3
3 - 2
Z Motor Replacement
EMT 1 Technical Manual