20. Position the POINT of the HOOK directly behind the SCARF of the needle. Leave
a THREAD distance between the POINT of the hook and the needle.
21. Tighten the colored hook screw and check that the setting is correct as shown in
Figures 3-27 and 3-28.
22. Press the key to rotate the the hook to access the other two hook screws
and tighten them securely.
23. After checking and setting hook timing as required, replace the needle plate,
rotary hook covers, and the bobbin case; then return the machine to its
operational state.
Hook Timing Adjustments Only
3 - 29
110344-01, Rev B
3. Embroidery Head Maintenance
Содержание EMT 1
Страница 6: ...This page intentionally left blank Table of Contents 110344 01 Revision B iv EMT 1 Technical Manual ...
Страница 44: ...This page intentionally left blank 2 30 X Beam Assembly EMT 1 Technical Manual Melco Embroidery Systems ...