CONTROL SYSTEM
U–49
U
1O
Water
temperature
sensor input
Water temperature
sensor
Depends on temperature
surrounding sensor
See Figure
4
•
Inspect for continuity
(Climate control unit—water
temperature sensor: 1O—A,
1I—B)
•
Inspect for short circuit
(Climate control unit—water
temperature sensor: 1O—A)
•
Inspect water temperature
sensor
•
Inspect terminal voltage of
climate control unit (2H, 2L)
1P
A/C Refrigerant
pressure switch
Fan switch at OFF
12
•
Inspect for continuity or
short circuit (Climate control
unit—refrigerant pressure
switch: 1P—A (Dual-
pressure type), 1P—C
(Triple-pressure type))
(Refrigerant pressure
switch—PCM: B—1AC)
•
Inspect refrigerant pressure
switch
•
Inspect PCM terminal
voltage (1AC)
(See
F–45 PCM
INSPECTION
)
Fan switch at 1st
position, A/C switch ON
Below 1.0
•
Inspect terminal voltage of
climate control unit (2H, 2L)
1Q
Evaporator
temperature
sensor input
signal
Evaporator
temperature sensor
Depends on temperature
surrounding sensor
See Figure
1
•
Inspect for continuity
(Climate control unit—
evaporator temperature
sensor: 1Q—A, 1I—B)
•
Inspect for short circuit
(Climate control unit—
evaporator temperature
sensor: 1Q—A)
•
Inspect evaporator
temperature sensor
•
Inspect terminal voltage of
climate control unit (2H, 2L)
1R
—
—
—
—
—
1S
Solar radiation
sensor input
Solar radiation
sensor
Incandescent light (
60W
)
shining on solar
radiation sensor from
distance of
approx.
100mm {3.9 in}
4.0
•
Inspect for continuity or
short circuit (Climate control
unit—solar radiation sensor:
1S—B, 1B—A)
•
Inspect terminal voltage of
climate control unit (1B)
•
Inspect solar radiation
sensor
Light to solar radiation
sensor block
Below 1.0
1T
GND
Ground
Under any condition
Below 1.0
•
Inspect for continuity
(Climate control unit—
ground: 1T—GND)
•
Inspect center panel
1U
Potentiometer
signal
Air mix actuator
Set temperature at MAX
COLD
0.6
•
Inspect for continuity or
short circuit (Climate control
unit—air mix actuator: 1U—
C)
•
Inspect air mix actuator
•
Inspect terminal voltage of
climate control unit (1B)
Set temperature at MAX
HOT
4.3
1V
—
—
—
—
—
Terminal
Signal
Connected to
Test condition
Voltage (V)
Action
Содержание 6 2002
Страница 104: ...F 4 LOCATION INDEX End Of Sie FUEL SYSTEM A6E390001006W01 Engine Room Side A6E3912W015...
Страница 151: ...F 36 EXHAUST SYSTEM A6E3914W002...
Страница 312: ...F 182 TROUBLESHOOTING QUICK DIAGNOSTIC CHART A6E398018881W02 A6E3980W001...
Страница 313: ...TROUBLESHOOTING F 183 F A6E3980W002...
Страница 314: ...F 184 TROUBLESHOOTING A6E3980W003...
Страница 315: ...TROUBLESHOOTING F 185 F End Of Sie A6E3980W004...
Страница 410: ...K 3 K...
Страница 411: ...K 4 LOCATION INDEX AUTOMATIC TRANSAXLE LOCATION INDEX A6E560001074W01 LOCATION INDEX A6E5600W001...
Страница 526: ...TROUBLESHOOTING K 115 K QUICK DIAGNOSIS CHART A6E568001030W04 A6E5680W001...
Страница 527: ...K 116 TROUBLESHOOTING End Of Sie A6E5680W002...
Страница 653: ...ON BOARD DIAGNOSTIC ABS TCS P 57 P...
Страница 701: ...TROUBLESHOOTING ABS TCS DYNAMIC STABILITY CONTROL P 105 P Vehicle with ABS TCS A6E6980W002...
Страница 702: ...P 106 TROUBLESHOOTING ABS TCS DYNAMIC STABILITY CONTROL Vehicle with DSC End Of Sie A6E6980W100...
Страница 819: ...OUTSIDE MIRROR S 60 2 THIS PAGE IS INTENTIONALLY LEFT BLANK End Of Sie...
Страница 971: ...T 76 WARNING AND INDICATOR SYSTEM Operating Order A6E8118W009...
Страница 1150: ...U 4 LOCATION INDEX End Of Sie CONTROL SYSTEM A6E850001042W01 L H D A6E8500W003 A6E8500W004...
Страница 1152: ...U 6 LOCATION INDEX R H D A6E8500W005 A6E8500W006...
Страница 1177: ...U 26 BASIC SYSTEM 12 Perform the refrigerant system performance test See U 13 REFRIGERANT SYSTEM PERFORMANCE TEST A6E8516W029...