Operation Instruction of S900 E Series Inverter
·
93
·
High→ low
5
Triangular wave
6
Winding
7
Inverter setting mode
P502
PLC running mode Initial value: 0
Range
0-4
Unit
1
Content:
0: PLC stop running after a week
1: PLC pause mode, stop running after a week
2: PLC cycle running
3: Cycle running of PLC pause mode
4: After running for a week, PLC continues
running by the end of running frequency
PLC running mode determines running status of internal multi-
speed, either running one circle or cycle running. P502 is only valid
when PLC starts up.
PLC pause mode means that when completing every speed in the
running process of internal multi-speed, the speed will be down,
stop, and accelerate to the next speed. The illustration is as below:
Frequency
Time
Users may select proper running mode according to actual
conditions.
P503
Multi-speed 1 Initial value: 10.0
P504
Multi-speed 2 Initial value: 15.0
P505
Multi-speed 3 Initial value: 20.0
P506
Multi-speed 4 Initial value: 25.0