10
·
·
11
·
Chapter 3 Installation of the Inverter
Chapter 3
Installation of the Inverter
3-1 Installation environment and requirements
Environment of installation has direct effect on the inverter's life. If
the inverter is used in the environment that does not accord with
the allowed range of the operation instruction, and may lead to the
inverter protection or fault.
About the inverter's installation environment, please ensure it is in
accordance with the following condition:
(1) Environment temperature from -10
℃
to +40
℃
(2) Environment humidity 0~95% without condensing
(3) Away from direct sunlight
(4) The environment does not contain corrosive gas and liquid
(5) The environment does not contain dust, floating fiber and metal dust.
(6) Far away from radioactive materials and combustible substances
(7) Far away from electromagnetic interference sources (as welder,
high-powered machines)
(8) The installation surface shall be firm. Without vibration, the
vibration cannot be avoided, please add anti-vibration spacer to
reduce vibration.
(9) Please install the inverter to a location where it is good for
ventilation, inspection and maintenance, and away from heating unit
(as brake resistor).
(10) Preserved enough space for inverter installation, especially
for multiple inverters installation, please pay attention to the laying
position of the inverter, and install an extra cooling fan to keep the
environment temperature lower than 45
℃
.