32
·
Operation Instruction of S900 E Series Inverter
·
33
·
Function
Parameters
Name
Setting Range
Minimum
Setting
increments
Initial value
Refer
To
Page
I/O functions
P313 Direction of
high analog
0/1
1
0
66
P314
Analog input
reverse
selection
0/1
1
0
67
P315 Input terminal
FWD (0~32)
0: Invalid
1: Jog
2: Jog Forward
3: Jog reverse
4: Forward/ reverse
5: Run
6: Forward
7: Reverse
1
6
69
P316 Input terminal
REV (0~32)
8: Stop
9: Multi-speed 1
10: Multi-speed 2
11: Multi-speed 3
12: Multi-speed 4
13: Accleration/
Deceleration terminal 1
14: Accleration/
Deceleration terminal 2
15: Frequency
increase signal (UP)
16: Frequency
decrease signal
(DOWN)
17: Emergency stop
signal
1
7
69
P317 Input terminal
S1 (0~32)
1
1
69
P318 Input terminal
S2 (0~32)
1
18
69
P319
Input terminal
S3
(0~32)
18:Inverter reset
signal
19: PID in running
20: PLC in running
21: Start signal for
timer 1
22: Start signal for
timer 2
23: Counter pulse
signal
24: Counter reset
signal
25: Memory clear
26: Start winding
operation
1
15
69
P320
Input terminal
S4
(0~32)
1
16
69
P321
(0~32)
Reserved
1
8
69
P322
(0~32)
Reserved
1
9