Chapter 7 Detailed Explanations of Functional Parameters
(1) Connection illustration
(2) Parameter setting
PLC operation direction setting: (P533 setting)
Rate of
segment
1
Rate of
segment
2
Rate of
segment
3
Rate of
segment
4
Dominant
frequency
4
3
2
1
0
→ position (bit)
0
1
0
1
0
→ run direction <0 is
forward, 1 is Reverse
0×24
1×23
0×22
1×21
0×20
→ transfer to decimal
system
The binary system number 01010 is transferred to decimal system
number: 1×21+1×23+8=10
Define to: P533=10
The parameter defines to:
P101=3
(Keyboard potentiometer setting mode: dominant
frequency is controlled by potentiometer)
P102=2
(Running setting option: Multifunction end input)
P105=60
(The max. frequency is 60HZ)
P107=10
P108=10 (acceleration/deceleration time 10S)
P314=6
(S1 end is running forward)
P318=8
(S2 end is ceasing)