24
·
Operation Instruction of S900 E Series Inverter
·
25
·
5-2 Operating panel operation instruction
(1) Parameter setting <taking modifying P104 reverse Valid setup
as example>
Program
Key name
Display
Description
1
Power on
F00.0
STOP
FWD
①
Display the frequency
setting (initial display).
②
The inverter is standing by.
2
Press
P000
STOP
FWD
To enter the parameter setup
state, and the first letter blinks
(means modifiable item)
3
Press
for
four times
P004
STOP
FWD
The digit is modified into "4"
from "0".
4
Quickly press
2 times
(quick press
means shift)
P004
STOP
FWD
Shift leftward for two digits
and the third digit will clicker.
5
Press
for
once
P104
STOP
FWD
The digit is modified into "1"
from "0".
6
Press and hold
0001
STOP
FWD
Enter the parameter setting
interface.
7
Press
0000
STOP
FWD
Modified "1" into "0".
8
Press and hold
P105
STOP
FWD
To confirm that the value
"P104" has been modified.
9
Press
F00.0
STOP
FWD
Return back to the initial
display.
Note:
1. Pressing
can interrupt the modification and return back to
the main display interface.
2. When a modification is confirmed, An Err may be displayed to
show the parameter modification is failed.
(2) Status display and inquiry
Parameter set: the frequency for the startup and shutdown (P102=0)