60
·
·
61
·
Chapter 7 Detailed Explanations of Functional Parameters
Adjusting parameter P208 can increase voltage and obtain higher
torque.
Attention: Too big setting may cause motor overheating. Increase
the setting step by step until you get the requested starting torque.
P209
Rated motor voltage Initial value : 380.00V
Setting range
0-500.00
Unit
0.01
P210
Rated Motor current Initial value : *
Setting range
Unit
0. 1
P211
No load current ratio of motor Initial value : 40
Setting range
0-100
Unit
1
P212
Rated motor rotation speed Initial value : 1420
Setting range
0-6000
Unit
1
P213
Numher of motor poles Initial value : 4
Setting range
0-10
Unit
1
P214
Rated motor slip Initial value : 2.5
Setting range
0-100
Unit
0. 1
Please set above parameters according to the motor rating.
P209 Rated voltage motor
Please set rated voltage of motor according to voltage value on
motor nameplate.
100%
Torque
compensation
V