Operation Instruction of S900 E Series Inverter
·
71
·
Settings
0: Invalid
1: Jog
2: Jog Forward
3: Jog reverse
4: Forward/ reverse
5: Running
6: Forward
7: Reverse
8: Stop
9: Multi-speed selection 1
10: Multi-speed selection 2
11: Multi-speed selection 3
12: Multi-speed selection 4
13: Acceleration/ deceleration selection 1
14: Acceleration/ deceleration selection 2
15: Frequency increasing signal Up
16: Frequency decreasing signal Down
17: Coasting stop
18: Fault reset
19: PID function enable
20: PLC function enable
21: Timer 1 start up
22: Timer 2 start up
23: Counter pulse input
24: Counter reset
25: PLC memory clear
26: Winding operation start
0: Invalid
Set as empty terminal, no function
1: Jog
Set as JOG (inching), usually used in trial running, common inching
is operated by 5Hz,
2: Jog Forward
Set as JOG forward.
3: Jog reverse
Set as JOG reverse.
4: Forward/ reverse