Chapter 6 Table of Function Parameters
Function
Parameters
Name
Setting Range
Minimum
Setting
increments
Initial value
Refer
To
Page
I/O functions
P323 Output terminal
M01 (0~32)
0: Invalid
1: In running
2: Frequency reached
3: Alarm
4: Zero speed
5: Frequency 1
reached
6: Frequency 2
reached
7: Accleration
8: Deceleration
9: Indication for under
voltage
10: Timer 1 reached
11: Timer 2 reached
12: Indication for
completion of phase
13:Indication for
completion of
procedure
14: PID maximum
15: PID minimum
16: 4-20mA
disconnection
17: Overload
18: Over torque
26: Winding operation
completed
27: Counter reached
28: Intermediate
counter reached
29:Water supply by
constant voltage
“1” turn on
“0” turn off
1
01
75
P324 Reserved
1
02
75
P325
Alarm output
terminal RA,
RB, RC (0~32)
1
03
75
P326 Output terminal
FOV (0~7)
0: Frequency output
1: current output
2: Dc bus voltage
3: Ac voltage
4: Pulse
output,1pulse/ Hz
5: 2pulses/Hz
6: 3 pulses/Hz
7: 6 pulses/Hz
1
0
79
P327 Reserved
1
1
79