Hydraulics
The FM100 Float Module’s hydraulic system drives the
fl
oat module feed draper, header drapers, and knife drives.
The combine’s hydraulic system drives the reel hydraulics.
The
fl
oat module frame acts as an oil reservoir. Refer to
5.2.1 Recommended Fluids and Lubricants, page 296
for
oil requirements.
5.4.1
Checking Oil Level in Hydraulic Reservoir
Check the hydraulic oil level in the reservoir every 25 hours.
1. Check the oil level using the lower sight (A) and
the upper sight (B) with the cutterbar just touching
the ground.
NOTE:
Check the level when the oil is cold and with
center-link retracted.
2. Ensure the oil is at the appropriate level for the terrain
as follows:
•
Hilly terrain (C):
Maintain level so lower sight (A) is
full, and upper sight (B) is up to one-half
fi
lled.
•
Normal terrain (D):
Maintain level so lower sight (A)
is full, and upper sight (B) is empty.
•
Level ground (E):
For slopes of 6° or less, oil level
may be kept slightly lower if desired. Maintain level
so lower sight (A) is one-half
fi
lled or slightly higher.
NOTE:
It may be necessary to slightly reduce the oil level
when ambient temperatures are above 95°F (35°C) to
prevent over
fl
ow at the breather when normal operating
temperatures are reached.
Figure 5.27: Oil Level Sight Glass
5.4.2
Adding Oil to Hydraulic Reservoir
Follow this procedure to top up the oil in the hydraulic reservoir. To change the hydraulic oil, refer to
Changing Oil in Hydraulic Reservoir, page 321
DANGER
To avoid bodily injury or death from unexpected start-up of machine, always stop engine and remove key
from ignition before leaving operator’s seat for any reason.
147831
320
Revision A
Содержание FlexDraper FD1 Series
Страница 2: ...FD1 Series FlexDraper Header for Combines Published April 2016 ...
Страница 3: ...Declaration of Conformity 147831 i Revision A ...
Страница 4: ...147831 ii Revision A ...
Страница 5: ...147831 iii Revision A ...
Страница 6: ...147831 iv Revision A ...
Страница 8: ......
Страница 10: ......
Страница 34: ......
Страница 40: ...PRODUCT OVERVIEW Figure 2 1 Header Width 147831 22 Revision A ...
Страница 189: ...OPERATION Figure 3 260 Flow Chart for Setting the Sensitivity of the Float Optimizer 147831 171 Revision A ...
Страница 462: ......
Страница 484: ......
Страница 508: ......
Страница 509: ......