Every 250 Hours
Use high temperature extreme pressure (EP2) performance with 1% max molybdenum disulphide (NLGI Grade 2)
lithium base unless otherwise speci
fi
ed.
Figure 5.9: Every 250 Hours
A - Upper Cross Auger U-joint and Bearing
12
B - Upper Cross Auger Bearing (Two Places)
C - Reel U-joint (One Place)
D - Flex Linkage (Two Places) - Both Sides
12. U-joint has an extended lubrication cross and bearing kit. Stop greasing when greasing becomes dif
fi
cult or if
U-joint stops taking grease. Overgreasing will damage U-joint. Six to eight pumps are suf
fi
cient at
fi
rst grease
(factory). Decrease grease interval as U-joint wears and requires more than six pumps.