7. Using a voltmeter, measure the voltage between the
ground (Pin 2) and signal (Pin 3) wires of the AHHC
sensor (A) at the back of the side frame. It should be
at the low voltage limit for the combine—refer to Table
3.13 Combine Voltage Limits, page 101
.
8. If the sensor voltage is not within the low and high
limits, or if the range between the low and high limits is
insuf
fi
cient, adjust the voltage limits. Refer to
Voltage Limits (One-Sensor System), page 106
.
9. Repeat at the opposite side.
Figure 3.133: Optional Two-Sensor Kit –
RH Sensor
Adjusting Voltage Limits (One-Sensor System)
DANGER
To avoid bodily injury or death from unexpected start-up of machine, always stop engine and remove key
from ignition before leaving operator’s seat for any reason.
147831
106
Revision A